Pexgol

Allowable Pressure and Temp

Allowable working pressures [bar] for conveying water in Pexgol pipes, with a safety factor C = 1.25

 

 

°C

 

 

Class 6

Class 8

Class 10

Class 12

 

Class 15

 

Class 19

 

Class 24

 

Class 30

 

Pipe series (S)

12.5

10

7.6

 

 6.3

5

4

3.2

 

 2.5

Standard dimension ratio (SDR)

26

21

16.2

 13.6

11

9

7.4

6

10°

6.8

8.5

11.20

13.50

17.00

21.40

26.90

33.89

20°

6.0

7.6

9.90

11.90

15.00

18.90

23.80

29.99

30°

5.3

6.7

8.80

10.60

13.30

16.80

21.10

26.59

40°

4.7

5.9

7.80

9.40

11.80

14.90

18.70

23.56

50°

4.1

5.2

7.00

8.30

10.50

13.20

16.70

21.04

60°

3.8

4.8

6.30

7.50

9.50

11.90

15.00

18.90

70°

3.4

4.3

5.60

6.70

8.50

10.70

13.40

16.88

80°

3.0

3.8

5.10

6.10

7.50

9.50

12.00

15.12

90°

2.7

3.4

4.50

5.40

6.80

8.60

10.90

13.73

95°

2.6

3.2

4.10

4.90

6.40

8.10

10.30

12.98

100°

2.1

2.7

3.5

4.2

5.5

7.0

9.0

11.2

105°

1.8

2.2

2.8

3.4

4.5

5.5

7.0

8.7

110°

1.5

1.9

2.40

2.90

3.80

4.70

5.90

7.43

 

Allowable working pressures [psi] for conveying water in Pexgol pipes, with a design factor (DF) =0.8.

 Safety factor C = 1.25

°F Class 6 Class 8 Class 10 Class 12 Class 15 Class 19 Class 24 Class 30
Pipe series (S)
12.5 10 7.6 6.3 5 4 3.2 2.5
Dimension ratio (DR)
26 21 16.2 13.6 11 9 7.4 6
50 99 123 162 196 247 310 390 491
70 83 105 137 164 207 261 329 414
90 72 91 120 144 181 228 287 361
100 72 90 119 143 180 227 285 360
120 61 77 104 123 155 195 247 311
140 55 70 91 109 138 173 218 274
160 49 61 80 96 122 153 192 241
180 42 54 72 86 106 134 170 214
190 40 50 67 80 101 128 162 204
200 39 47 61 73 95 120 153 192
210 31 40 51 62 81 103 132 164
220 26 32 41 50 66 81 102 127
230 22 28 35 42 55 68 86 108

 